Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 3680 (Determination of flash/no flash - Rapid equilibrium closed cup method)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
ca. 158 °C
Atm. press.:
ca. 1 013.25 mBar

Applicant's summary and conclusion