Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 October 2018 (Experimental starting date) - 17 January 2019 (Experimental completion date)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
30 May 2008
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
21 °C
Atm. press.:
101.2 kPa

The observed flash point was corrected for the atmospheric pressure using the following Equation: C + 0.23 (101.325 - p); C = observed flash point (°C), p = ambient atmospheric pressure (kPa)

Atmospheric pressure: 101.2 kPa Observed flash point: 21.0 °C Corrected flash point: 21.0 °C

Interpretation of results:
Category 2 (highly flammable liquids) based on GHS criteria
Conclusions:
The flash point of the test item has been determined to be 21 ± 2 °C.
Executive summary:

The observed flash point was corrected for the atmospheric pressure. The flash point of the test item has been determined to be 21 ± 2 °C.

Description of key information

The flash point of the test item has been determined to be 21 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
21 °C

Additional information