Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: ASTM D6450-12e1
Principles of method if other than guideline:
The flash point (closed-cup) can be determined according to “10.2 Procedure A” in ASTM D6450-12E1 by a Pensky-Martens closed-cup tester. After the sample is loaded into the testing cup of the tester, heat it evenly. When the sample temperature approaches the flash point, ignition could be applied and note the temperature when flash occurs.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
ca. 55 °C
Atm. press.:
ca. 1 atm
Conclusions:
The flash point of this material is 55.0°C.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
55 °C

Additional information