Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
Internal company data provided a flash point measurement using a standard closed cup method.
GLP compliance:
no
Type of method:
closed cup
Flash point:
91.8 °C
Atm. press.:
ca. 101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flashpoint of the substance was determined to be 91.8°C using a closed cup method.

Description of key information

The flashpoint of the substance was determined using a closed cup method.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
91.8 °C