Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
GLP compliance:
yes
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
0.56
Temp.:
22 °C
pH:
ca. 7

Applicant's summary and conclusion

Conclusions:
The partition coefficient (n-octanol/water) of the test item at 21,4 to 22 °C and a mean pH value of 7,0 was determined to be log Kow = 0.56.
Executive summary: