Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
other: KS M 2010:2008
Version / remarks:
“Testing methods for flash point of crude oil and petroleum products -Determination of flash point - Tag closed cup method”,
Qualifier:
according to
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
other: Tag Closed Cup Flash Tester

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
> 93 °C
Atm. press.:
101.3 kPa
Remarks on result:
no flash point up to 100°C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met