Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 21 March 2018 to 21 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP
Qualifier:
according to guideline
Guideline:
other: ASTM D6450
Deviations:
no
Principles of method if other than guideline:
The test was performed by use of a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method according to ASTM D 6450
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH automatic flash point tester
Key result
Flash point:
> 200 °C
Atm. press.:
98.1 kPa
Remarks on result:
other: No flash point up to 200°C

Preliminary test was performed from 30 to 200 °C with negative result.

The test item was measured with two parallel tests.

The measured flash point of LAB 4448 was: no flash point was observed up to 200°C.

Interpretation of results:
GHS criteria not met
Conclusions:
The tested substance "LAB 4448" did not show any flash point up to 200°C.
Executive summary:

The substance "LAB 4448" was tested for its flash point according to ASTM D 6450 and in compliance with GLP.

The MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method was used to determine the flash point. Preliminary test was performed from 30 to 200 °C with negative result. Then the definitive experiment was performed with two parallel tests and no flash point was observed up to 200°C.

The substance "LAB 4448" has no flash point up to 200°C and it is not classified as flammable according to the CLP regulation 1272/2008.

The Flash point study is acceptable, and satisfies the requirements of the method ASTM D 6450.

Description of key information

The tested substance "LAB 4448" did not show any flash point up to 200°C. "LAB 4448" is not classified as flammable according to the CLP regulation 1272/2008.

Key value for chemical safety assessment

Additional information

The substance "LAB 4448" was tested for its flash point according to ASTM D 6450 and in compliance with GLP.

The MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method was used to determine the flash point. Preliminary test was performed from 30 to 200 °C with negative result. Then the definitive experiment was performed with two parallel tests and no flash point was observed up to 200°C.

The substance "LAB 4448" has no flash point up to 200°C and it is not classified as flammable according to the CLP regulation 1272/2008.