Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
pour and tap (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
Haematoxylin
EC Number:
208-237-3
EC Name:
Haematoxylin
Cas Number:
517-28-2
Molecular formula:
C16H14O6
IUPAC Name:
haematoxylin

Results and discussion

Densityopen allclose all
Key result
Type:
pour density
Density:
ca. 550 kg/m³
Temp.:
20.2 °C
Key result
Type:
tap density
Density:
ca. 730 kg/m³
Temp.:
20.2 °C

Any other information on results incl. tables

Pour Density: Dp

 

Assay No.1

Assay No.2

Mass of test item M (g)

118.7

121.6

Volume of test item V1(mL)

220

220

Pour Density Dp= M/V1(g/mL)

0.54

0.55

Arithmetic Mean

0.55 g/mL at 20.2 °C

550 kg/m3at 20.2 °C

1.1.1.     Tap Density: DT

 

Assay No.1

Assay No.2

Mass of test item M (g)

118.7

121.6

Volume of test item V2(mL)

164

166

Tap Density DT= M/V2(g/mL)

0.72

0.73

Arithmetic Mean

0.73 g/mL at 20.2 °C

730 kg/m3at 20.2 °C

 

Applicant's summary and conclusion

Conclusions:
The Pour Density DP was determined 550 kg/m3 at 20.2 °C under the specified testing conditions.
The Tap Density DT was determined 730 kg/m3 at 20.2 °C under the specified testing conditions.
Executive summary:

The Pour Density DPwas determined 550 kg/m3at 20.2 °C under the specified testing conditions.

The Tap Density DTwas determined 730 kg/m3at 20.2 °C under the specified testing conditions.