Registration Dossier

Physical & Chemical properties

Stability: thermal, sunlight, metals

Currently viewing:

Administrative data

Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
other information
Study period:
19 Jun 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Preliminary test to determine if boiling point should be determined at reduced pressure. Test performed using ARC (Accelerating Rate Calorimeter).
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

For thermal stability study

Operating temperature
Key result
Operating temp.:
>= 40 - <= 400 °C

Any other information on results incl. tables

Start temperature of exothermic reaction: 96.1 °C

Exothermic reaction of the test item would result in the polymerization of the sample compound. The start temperature of exothermic reaction is almost the same as the boiling temperature.