Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.06.2018-13.06.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Date of Receipt May 09, 2018
The following information was provided by the sponsor
Identification Polyflow 130
Appearance Yellow to amber colored liquid
Chemical Name Amines, N-tallow alkyltrimethylenedi-,reaction products with epichlorohydrin
Batch No. ST-637
CAS No. 93821-29-5
Manufacturing date March, 2018
Expiry date Feb, 2020
Stability The product is stable under storage at normal ambient temperature
Storage conditions Room Temperature (20 to 30ºC)
Safety precautions Aprons, masks, caps, gloves and goggles were used to ensure the health and safety of the personnel
Key result
Flash point:
ca. 85.1 °C
Atm. press.:
ca. 1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The Flash Point, determined by the Pensky-Martens Closed Tester method, of the liquid test item was 85.1°C at 1013hPa.
Executive summary:

The study was conducted to determine Flash Point for test item, polyflow 130 in accordance with current EEC testing guidelines usingPensky-Martens apparatus. The Flash Point of the liquid test item was 85.1 °C.

Description of key information

The Flash Point (Polyflo130;EC A.9): 85.1°C at 1013hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
85.1 °C

Additional information

The study was conducted to determine Flash Point for test item, polyflow 130 in accordance with current EEC testing guidelines usingPensky-Martens apparatus. The Flash Point of the liquid test item was 85.1 °C.