Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous

Results and discussion

Flash point
Key result
Flash point:
237 °C
Atm. press.:
1 003 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item Tocopherols Concentrate has a flash point of 237.0 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).