Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Type of method:
static method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.23 kPa
Conclusions:
The result showed that the vapor pressure of the test item was 0.23 kPa(20.0°C).

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0.23 kPa
at the temperature of:
20 °C