Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Feb - June 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
< 0 Pa
Key result
Test no.:
#2
Temp.:
ca. 25 °C
Vapour pressure:
< 0 Pa

A log p versus 1/T curve could not be obtained for the test substance in the range of 170°C and 190°C. The coefficient of correlation (r) was < 0.99. It indicated that the weight loss was obtained due to reaction and/or decomposition of the test substance. With the vapour pressure test the test substance was kept at elevated temperature for much longer intervals than during the melting and boiling temperature study. Reaction and/or decomposition consequently occurred at lower temperatures which was also observed by discoloration of the test substance from beige to grey/brown. Based on the results obtained the weight loss of the test substance was compared with the results of chrysene obtained by the validation test.

The weight loss of the test substance at 170°C, 180°C, 190°C and 200°C was lower than the weight loss of chrysene at the same temperatures. According to this the vapour pressure of the test substance was determined to be lower than that of chrysene.

Executive summary:

The isothermal TGA effusion method was applied for the determination of the vapour pressure of LEE011-A3.

The vapour pressure (Pa) of the test substance at

20°C (293K) was < 8.4 × 10-7

25°C (298K) was < 2.2 × 10 -6

Description of key information

The isothermal TGA effusion method was applied for the determination of the vapour pressure of LEE011-A3.

The vapour pressure (Pa) of the test substance at

20°C (293K) was < 8.4 × 10-7

25°C (298K) was < 2.2 × 10-6

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information