Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

In absence of the results from the Tier 2 study, the findings from the Tier 1 test is used. According to company information the half-life at 50 °C is about 10 hours.

Key value for chemical safety assessment

Half-life for hydrolysis:
120 h
at the temperature of:
50 °C

Additional information