Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 October 2017 to 20 July 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Description: Brown liquid
Purity: >90%


Contact with:
powdered cellulose
Duration of test (contact time):
> 0 - < 60 s
Key result
Sample tested:
reference mixture with 65% nitric acid + cellulose (1:1 ratio)
Parameter:
mean pressure rise time
Result:
>= 12.463 - <= 17.408 s
Remarks on result:
spontaneous ignition does not occur
Interpretation of results:
GHS criteria not met
Conclusions:
The sample was found to have a mean pressure rise time greater than that observed for the nitric acid reference sample. The test substance is therefore not considered to be an oxidising liquid.
Executive summary:

The oxidizing properties of the test material was conducted in a study performed to the standardized guideline EU Test Method A.21., under GLP conditions. The sample was found to have a mean pressure rise time greater than that observed for the nitric acid reference sample. The test substance is therefore not considered to be an oxidising liquid.

Description of key information

The oxidizing properties of the test material was conducted in a study performed to the standardized guideline EU Test Method A.21., under GLP conditions. The sample was found to have a mean pressure rise time greater than that observed for the nitric acid reference sample. The test substance is therefore not considered to be an oxidising liquid.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification