Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1994
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report Date:
1994

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
other:
Remarks:
Test substance melted during exposure to the flame. After removal of the flame, the test substance ceased to burn, so therefore it is classified as inflammable with respect to this test guideline.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Test substance melted during exposure to the flame. After removal of the flame, the test substance ceased to burn, so therefore it is classified as inflammable with respect to this test guideline.