Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 September 2017 - 12 September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch/Lot number: 2161004
Appearance: White to light yellow flakes
Purity: 99.41%
Expiry date: 31 January 2018
Storage conditions: Controlled room temperature (15-25°C, below 70RH%), protected from light
Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In the preliminary test the test item could not ignited. Based on the results of the preliminary test, no main test was performed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item considered flammable if the main test take less than 45 seconds. In all other cases the test item is not considered flammable.
The test item could not ignited. Therefore, the substance is considered not to be highly flammable.
Executive summary:

Two parallel flammability tests were performed. The tests were negative.

The test item is not highly flammable in the conditions of this test.

Description of key information

Two parallel flammability tests were performed. The tests were negative.

The test item is not highly flammable in the conditions of this test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item considered flammable if the main test take less than 45 seconds. In all other cases the test item is not considered flammable.

The test item could not ignited. Therefore, the substance is considered not to be highly flammable.