Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 20 March 2018 to 24 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
yes
Remarks:
see field below
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Principles of method if other than guideline:
remark of reviewer:
Several non-equilibrium methods are mentioned in the EC A.9 guideline. According to the study report the study was performed according to ISO Guide 2719 (Pensky-Martens closed cup). However, from the description of the test performance and the flash-point tester it was concluded that ASTM D7094 (modified continuously closed cup) is more applicable. ASTM D7094 is not mentioned in the EC A.9 guideline but is a commonly used and safer (low sample volume) alternative for the ISO 2719 method.
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Dynamic viscosity of test material:
no data

Test material

Constituent 1
Chemical structure
Reference substance name:
Tetrahydro-6-propyl-2H-pyran-2-one
EC Number:
211-820-5
EC Name:
Tetrahydro-6-propyl-2H-pyran-2-one
Cas Number:
698-76-0
Molecular formula:
C8H14O2
IUPAC Name:
tetrahydro-6-propyl-2H-pyran-2-one
Test material form:
liquid
Details on test material:
Appearance: Clear colourless to pale yellow liquid
Storage: In refrigerator (2-8°C)
Specific details on test material used for the study:
Boiling temperature: 259°C

Results and discussion

Flash point
Key result
Flash point:
122 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

Test 1: 122°C

Test 2: 124°C

As the difference between the results is ≤ 6°C, the lowest flash point value obtained was reported as the flash point of the substance.

Applicant's summary and conclusion

Interpretation of results:
other: not classified under CLP or GHS
Conclusions:
The flash point of the substance was determined to be 122°C (at 1013 hPa).
Executive summary:

The flash point of the substance was determined using the modified continuously closed cup ASTM D7094 method (GLP study).

The flash point was determined in duplicate obtaining a lowest value of 122°C (at 1013 hPa).

ASTM D7094 is not mentioned in the EC A.9 flash point guideline but is a commonly used and safer (low sample volume) alternative for the ISO 2719 Pensky Martens closed method.