Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
batch #115514/53
Key result
Flash point:
> 93 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the 55% substance solution in water, was investigated using a Pensky Martin semi-automatic closed cup flash point instrument and was found to be greater than >93 °C. The 55% substance solution in water is not flammable.
Executive summary:

The flash point of the 55% substance solution in water, was investigated using a Pensky Martin semi-automatic closed cup flash point instrument and was found to be greater than >93 °C.  The 55% substance solution in water is not flammable.

Description of key information

The substance is a solid that decomposes without melting at > 175 °C, therefore testing is not necessary.

However, the solution as supplied has been evaluated

Key value for chemical safety assessment

Additional information