Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental phase started: 2015-06-17; Experimental phase completed: 2015-07-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Version / remarks:
and EU Method A.2 (Boiling Temperature)
GLP compliance:
yes (incl. certificate)
Remarks:
Landesamt für Umwelt, Wasserwirtschaft und Gewerbeaufsicht; Kaiser-Friedrich-Straße 7; D-55116 Mainz
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous
Details on test material:
Stabilized EMIM BF4
Appearance: lightly yellow clear viscous liquid
Purity: 93.36% (EMIM+, HPLC); 86.68 % (BF4-, titration); 4.89% (Stabilizer, HPLC)
Homogenity: homogeneous

Results and discussion

Boiling point
Decomposition:
yes
Decomp. temp.:
418.6 °C
Remarks on result:
other: no boiling point can be stated for the tested substance following OECD 103 and EU method A.2

Applicant's summary and conclusion

Conclusions:
no boilingpoint can be stated for stabilized EMIM BF4 following OECD 103 and EU method A.2
Executive summary:

The boiling point was determined via DSC (differential scanning calorimetry)

No boiling point could be determined due to decomposition of the test item.