Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
not specified
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
not specified
Principles of method if other than guideline:
used a particle size distribution method
GLP compliance:
no
Other quality assurance:
other:
Remarks:
company protocols
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: bulk material
Type of distribution:
mass based distribution
Specific details on test material used for the study:
not specified
Remarks on result:
not measured/tested
Key result
Percentile:
D10
Mean:
ca. 15.77 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
Standard deviation not specified therefore entered as zero
Key result
Percentile:
D50
Mean:
ca. 50.98 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
Standard deviation not specified therefore entered as zero
Key result
Percentile:
D90
Mean:
ca. 98.2 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
Standard deviation not specified therefore entered as zero
Remarks on result:
not measured/tested
Conclusions:
10% of the particles are below 15.77 μm, 50% of the particles are below 50.98 μm and 90% of the particles are below 98.20 μm, width = 1.26, VMD = 54.92 μm

Description of key information

Additional information

10% of the particles are below 10.41 μm, 50% of the particles are below 46.17 μm and 90% of the

particles are below 145.16 μm, width = 2.15, VMD = 63,82 μm