Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

1
Chemical structure
Reference substance name:
Cinchocaine
EC Number:
201-632-1
EC Name:
Cinchocaine
Cas Number:
85-79-0
Molecular formula:
C20H29N3O2
IUPAC Name:
2-butoxy-N-[2-(diethylamino)ethyl]quinoline-4-carboxamide
Test material form:
solid: particulate/powder

Results and discussion

Mass median aerodynamic diameter:
1 070 µm
Geometric standard deviation:
26
Particle sizeopen allclose all
Key result
Percentile:
D90
Mean:
1 070 µm
St. dev.:
69
Key result
Percentile:
D50
Mean:
545 µm
St. dev.:
20
Key result
Percentile:
D10
Mean:
66 µm
St. dev.:
26

Applicant's summary and conclusion

Conclusions:
The particule size distrubition was performed using laser diffraction method. The aerodynamic diameters measured were :
- D10 = 66 µm ± 26
- D50 = 545 µm ± 20
- D90 = 1070 µm ± 69
Executive summary:

The particule size distrubition was performed using laser diffraction method. The aerodynamic diameters measured were :

- D10 = 66 µm ± 26

- D50 = 545 µm ± 20

- D90 = 1070 µm ± 69