Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
27th July 1995
Deviations:
no
GLP compliance:
no
Type of method:
capillary method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Key result
Atm. press.:
1 atm
Decomposition:
yes
Decomp. temp.:
180 °C
Sublimation:
no
Remarks on result:
other: The test material decomposes before melting occurs.

Applicant's summary and conclusion

Conclusions:
The study was performed according to OECD TG102 without deviations and therefore reliability of Klimisch 2 has been assigned. The test material decomposes before melting occurs at 180 °C.
Executive summary:

The melting point of the test material was determined experimentally using the capillary method in a non-GLP test according to OECD guideline 102. The test material decomposes before melting occurs at 180 °C.