Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
2-cyclohexylethyl acetate
EC Number:
244-543-3
EC Name:
2-cyclohexylethyl acetate
Cas Number:
21722-83-8
Molecular formula:
C10H18O2
IUPAC Name:
2-cyclohexylethyl acetate
Specific details on test material used for the study:
Designation in Test Facility: 17112908G
Date of Receipt: 29. Nov. 2017
Condition at Receipt Room temperature, in proper conditions
6.1.1 Specification
The following information concerning identity and composition of the test item was provid-ed by the sponsor.
Name Cyclohexyl ethyl acetate
Batch no. CP014-171101
Appearance colorless and transparent liquid
Composition Cyclohexyl ethyl acetate
Purity 99.85%
Homogeneity homogeneous
Expiry date 30. May 2019
Storage Room temperature (20 ± 5 °C)

The following additional information, also provided by the sponsor, was relevant to the conduct of the study, according to OECD 439:
CAS No. 21722-83-8
EINECS-No. 244-543-3
Stability in solvents unknown
Solubility unknown
Structural Formula /
SMILES Code not available

6.1.2 Storage
The test item was stored in the test facility in a closed vessel at room temperature (20 ± 5°C).

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
other: human-derived epidermal keratinocytes
Cell source:
other: a commercially available EpiDermTM-Kit, procured by MatTek.
Source strain:
not specified
Vehicle:
unchanged (no vehicle)
Details on test system:
Specification
The test system is a commercially available EpiDermTM-Kit, procured by MatTek.
The EpiDermTM tissue consists of human-derived epidermal keratinocytes which have been cultured to form a multi-layered, highly differentiated model of the human epidermis. It consists of organized basal, spinous and granular layers, and a multi-layered stratum corneum containing intercellular lamellar lipid layers representing main
lipid classes analogous to those found in vivo. The EpiDermTM tissues are cultured on specially prepared cell culture inserts.

Origin
EpiDermTM tissues were procured from MatTek In Vitro Life Science Laboratories, Brati-slava.
Designation of the kit: EPI-200-SIT
Day of delivery: 15. May 2018
Batch no.: 28610
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
30 µL test item
Duration of treatment / exposure:
1 hours and 35 minutes
Duration of post-treatment incubation (if applicable):
42 hours and 30 minutes
Number of replicates:
3

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
% tissue viability
Value:
ca. 133.9
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
Criterion Demanded Found
OD of negative control ≥ 0.8 and ≤ 2.8 1.3
% tissue viability
of positive control SDS ≤20% of negative control 2.9%
SD of mean viability of the
tissue replicates (%) ≤ 18% 11.1% (negative control)
0.4% (positive control)
4.5% (test item)

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The mean value of relative tissue viability of the test item was increased to 133.9% after the treatment. This value is above the threshold for skin irritation (50%). Therefore, the test item is considered as non-irritant to skin.