Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
> 300 °C
Atm. press.:
ca. 101.3 kPa
Remarks on result:
no flash point according to standard method

Any other information on results incl. tables

A pre-test was conducted and no flash point was observed up to 300°C (apparatus limitation). Moreover, the test item starts degrading approximately from 200°C (observation into the test cup).

The flash point of the reference substances glycerol and CRM respects the checking cards limits.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The corrected flash point of the test item was determined to be > 300°C”.