Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 2018
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: Knudsen cell
Key result
Temp.:
20 °C
Vapour pressure:
ca. 0 Pa
Key result
Temp.:
25 °C
Vapour pressure:
ca. 0 Pa
Conclusions:
20C - 4.33·10-7
25C - 1,11·10-6

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information

1,11E-6(25C)