Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2018
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 4 min
Key result
Test procedure:
burning rate test over 100 mm length
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The sample did not ignite when the test burner flame was applied. The flame of the burner did not transfer to the rest of the sample. burner flame exposure time: 30.60 and 120 s. Negative result.

Interpretation of results:
not classified based on GHS criteria
Conclusions:

It is not flammable according to method A.10.

Description of key information

it is not flammable according to method A.10.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

It is not flammable.