Registration Dossier

Administrative data

Endpoint:
viscosity
Data waiving:
study technically not feasible
Justification for data waiving:
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
Statement as presented in the study report: "The test item is a very viscous liquid. Due to its high viscosity, introducing the test item into the viscometer is technically not possible. The test item was therefore visually compared to a reference oil with known viscosity (Viscosity & Density Reference Standard type N18000; kinematic viscosity of 106285 mm2/s at 20°C; Paragon Scientific Ltd, Prenton, United Kingdom).

The test item was visually more viscous than the reference oil and has therefore a kinematic viscosity which is higher than the reference oil.

The test was performed at 19.9°C.

The kinematic viscosity of T106D is > 106285 mm2/s at 20°C."

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Results and discussion

Applicant's summary and conclusion