Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 May 2018 to 25 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item was found to not highly flammable in the preliminary test, therefore, a definitive test is not required.
Executive summary:

The flammability of the test item was investigated in an EC Method A.10 study. In the preliminary test the test item was found to be not highly flammable, and therefore, a definitive test is not required.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

In the preliminary test, the test item was determined to be not highly flammable, therefore, a definitive test was not required to be performed.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was investigated in a GLP compliant EC Method A.10 study that is fully acceptable for assessment of this endpoint.

Justification for classification or non-classification

The test item was determined not to be highly flammable in the preliminary test of an EC Method A.10 guideline study, and therefore, does not require a classification for flammability.