Registration Dossier

Physical & Chemical properties

Stability: thermal, sunlight, metals

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-08-17 - 2018-02-26
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Test substance thermally stable:
yes
Remarks:
up to 500°C
Key result
Operating temp.:
>= 25 - <= 500 °C
Conclusions:
The test item HIDT (main component) showed an endothermic effect in the temperature range of 280 – 350 °C and no further thermal effects up to the maximum temperature of 500 °C.

Executive summary:

The test item HIDT (main component) showed an endothermic effect in the temperature range of 280 – 350 °C and no further thermal effects up to the maximum temperature of 500 °C.

Description of key information

Stable up to 500°C

Additional information

Justification for classification or non-classification

Stable up to 500°C