Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 February 2018 - 02 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
29 July 2016
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
4,4'-Isopropylidenediphenol, oligomeric reaction products with 1-chloro-2,3-epoxypropane, reaction products with trimethylhexane-1,6-diamine
EC Number:
500-332-0
EC Name:
4,4'-Isopropylidenediphenol, oligomeric reaction products with 1-chloro-2,3-epoxypropane, reaction products with trimethylhexane-1,6-diamine
Cas Number:
153195-44-9
Molecular formula:
(C15 H16 O2 . C9 H22 N2 . C3 H5 Cl O)x
IUPAC Name:
4,4'-Isopropylidenediphenol, oligomeric reaction products with 1-chloro-2,3-epoxypropane, reaction products with trimethylhexane-1,6-diamine
Test material form:
liquid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
recommended by guideline
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm™ Reconstructed Human Epidermis Model Kit
- Tissue batch number(s): 25883
- Delivery date: 27 February 2018
- Date of initiation of testing: 28 February 2018

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37 °C
- Temperature of post-treatment incubation (if applicable): 37 °C, 5% CO2

REMOVAL OF TEST MATERIAL AND CONTROLS
- Rinsing was achieved by filling and emptying each tissue under a constant soft stream of Dulbecco’s Phosphate Buffered Saline (DPBS) (without Ca++ Mg++) for approximately 40 seconds, to gently remove any residual test item. Excess DPBS was removed by blotting the bottom of the tissue insert with tissue paper. Each tissue was placed into the prepared holding plate until all tissues were rinsed.
- Observable damage in the tissue due to washing: no


MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1.0 mg/mL
- Incubation time: 3 hours
- Spectrophotometer: Labtech LT-4500 microplate reader

NUMBER OF REPLICATE TISSUES: duplicates

CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- killed tissues
- Procedure used to prepare the killed tissues (if applicable): freeze killed
- N. of replicates : duplicates
- Method of calculation used: True viability = mean OD tvt-(OD tkt-OD ukt)

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.
< 25% after 3 min exposure: Sub-category 1A
≥ 25% after 3 min exposure: Combination of sub-categories 1B-and-1C
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
yes, concurrent MTT non-specific colour control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 μL
- Concentration (if solution): 100%

NEGATIVE CONTROL
- Sterile distilled water
- Amount(s) applied (volume or weight): 50 μL

POSITIVE CONTROL
- Potassium Hydroxide
- Amount(s) applied (volume or weight): 50 μL
- Concentration (if solution): 8.0 N
Duration of treatment / exposure:
3-Minutes and 60-Minutes
Duration of post-treatment incubation (if applicable):
not applicable
Number of replicates:
2

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 minute exposure
Value:
37.8
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
60 minute exposure
Value:
25.6
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: no
- Direct-MTT reduction: The MTT solution containing the test item turned purple and therefore the test item was demonstrated to directly reduce MTT. Therefore, an additional procedure using freeze-killed tissues was performed. The results of the freeze-killed tissues were subtracted from the mean OD of the test item treated viable tissues to obtain the true amount of MTT reduction that reflects metabolic conversion only:
True viability = mean OD tvt-(OD tkt-OD ukt)
- Colour interference with MTT: The solution containing the test item did not become colored. This was taken to indicate the test item did not have the potential to cause color interference.

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The mean OD570 for the negative control treated tissues was 1.634 for the 3 Minute exposure period and 1.426 for the 60 Minute exposure period. The negative control acceptance criteria were therefore satisfied.
- Acceptance criteria met for positive control: The relative mean tissue viability for the positive control treated tissues was 5.1% relative to the negative control following the 60 Minute exposure period. The positive control acceptance criterion was therefore satisfied.
- Acceptance criteria met for variability between replicate measurements: In the range 20 to 100% viability the Coefficient of Variation between the two tissue replicates of each treatment group did not exceed 30%. The acceptance criterion was therefore satisfied.

Any other information on results incl. tables

Mean OD570 Values and Viabilities for the Negative Control Item, Positive Control Item and Test Item

Tissue

Exposure Period

Mean OD570of individual tissues

Mean OD570of duplicate tissues (tvt)

Corrected Mean OD570(tvt-[tkt-ukt])

Standard Deviation

Coefficient of Variation

(%)

Relative Mean Viability (%)

Negative Control

3 Minutes

1.699

1.634

 

0.092

5.6

100*

1.569

 

60 Minutes

1.461

1.426

 

0.050

3.5

1.390

 

Positive Control

3 Minutes

0.078

0.081

 

0.004

na

4.9

0.083

 

60 Minutes

0.070

0.073

 

0.004

na

5.1

0.075

 

Test Item

3 Minutes

0.605

0.681

0.617

0.107

15.7

37.8

0.756

60 Minutes

0.522

0.496

0.365

0.037

7.4

25.6

0.470

 

 

Correction factor:
3 minute exposure corrected mean OD570=
       0.176   (tkt) – 0.112      (ukt) = 0.064

60 minute exposure corrected mean OD570=     0.252   (tkt) – 0.121      (ukt) = 0.131

 

 

OD= Optical density

tvt =Treated killed tissues

tkt=Untreated killed tissues

ukt = Untreated killed tissues

*=  The mean % viability of the negative control tissue is set at 100%

na= Not applicable

Applicant's summary and conclusion

Interpretation of results:
Category 1B (corrosive) based on GHS criteria
Conclusions:
In this test, the test item BADGE-TMD adduct was considered to be corrosive (Category 1B/C).
Executive summary:

The purpose of this test is to evaluate the corrosivity potential of BADGE-TMD adduct using the EpiDerm™ Human Skin Model after treatment periods of 3 and 60 minutes.

Corrosion is directly related to cytotoxicity in the EpiDerm™ tissue. Cytotoxicity is determined by the reduction of MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl-tetrazolium bromide) to formazan by viable cells in the test item treated tissues relative to the corresponding negative control. The results are used to make a prediction of the corrosivity potential of the test item.

Duplicate tissues were treated with the test item for exposure periods of 3 and 60 minutes. Negative and positive control groups were treated for each exposure period. The test item was found to directly reduce MTT and therefore additional non-viable tissues were incorporated into the testing for correction purposes. At the end of the exposure period the test item was rinsed from each tissue before each tissue was taken for MTT‑loading. After MTT-loading each tissue was placed in 2 mL of Isopropanol for MTT extraction.

At the end of the formazan extraction period each well was mixed thoroughly and triplicate 200 mL samples were transferred to the appropriate wells of a pre-labeled 96‑well plate. The optical density (OD) was measured at 570 nm (OD570).

Data are presented in the form of percentage viability (MTT reduction in the test item treated tissues relative to negative control tissues).

 

The relative mean viabilities for each treatment group were as follows:

Exposure Period

Percentage Viability

Negative Control

Positive Control

Test Item

3 minute

100

4.9

37.8

60 minute

100

5.1

25.6

 

In this test, the test item BADGE-TMD adduct was considered to be corrosive.