Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
no

Test material

Reference
Name:
Unnamed

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
ca. 245 °C
Atm. press.:
ca. 101.3 kPa

Any other information on results incl. tables

    

Injection

No.

 

Injection volume

of the sample

 100 μL  150 μL  200 μL  
 Whether any cool-flame occurred  No No   No  
1            Test temperature (℃)  254  248  248  
 

Whether any hot-flame occurred

in 10 min

 Yes Yes   Yes  
 Delay time (s)  30  41  43  
 Hot-flame temperature (℃)  260  252  254  
          2  Test temperature (℃)  251  245  245  
 

Whether any hot-flame occurred

in 10 min

 Yes  No  Yes  
 Delay time (s)  40  48  
 Hot-flame temperature (℃)  257  253  
3            Test temperature (℃)  248    242  
 

Whether any hot-flame occurred

in 10 min

No   /  No  
 Delay time (s)  /  /  /  
 Hot-flame temperature (℃)  /    /  

According to the test data, the auto-ignition temperature of the sample can be confirmed to

be 245℃ (101.3 kPa).

Applicant's summary and conclusion

Conclusions:
According to the test data, the auto-ignition temperature of the sample can be confirmed to be 245℃ (101.3 kPa).