Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D7094-12e1
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Reference
Name:
Unnamed

Results and discussion

Flash pointopen allclose all
Key result
Flash point:
ca. 68 °C
Atm. press.:
ca. 101.3 kPa
Key result
Flash point:
ca. 68.2 °C
Atm. press.:
ca. 101.3 kPa

Any other information on results incl. tables

The average value of testing results, 68.1℃, can be considered valid based on:

- the deviation between the expected value and the actual result was less than 10℃

- The difference between two independent test results was not more than 2℃.

Applicant's summary and conclusion

Conclusions:
Flash Point (closed-cup) 68.1℃