Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Technical Guidance Document EUR 20268 Determination of Particle Size Distribution
Version / remarks:
The determination was carried out using a procedure designed to be compatible with that given in European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
Deviations:
no
GLP compliance:
yes
Type of method:
determination of fibre length and diameter distributions
Type of particle tested:
other: powder
Type of distribution:
mass based distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
3,4-Dimethoxybicyclo[4.2.0]octa-1,3,5-triene-7-carbonitrile
EC Number:
609-091-7
Cas Number:
35202-54-1
Molecular formula:
C11H11NO2
IUPAC Name:
3,4-Dimethoxybicyclo[4.2.0]octa-1,3,5-triene-7-carbonitrile

Results and discussion

Mass median aerodynamic diameter:
>= 10 - < 100 µm
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
<= 10 µm
Distribution:
>= 50 %
No.:
#2
Size:
0 - < 100 µm
Distribution:
ca. 7.2 %

Applicant's summary and conclusion

Conclusions:
The percentage of test item having an inhalable particle size of less than 100 μm was determined to be 7.2%.