Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04/28/2017 - 08/22/2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Key result
Flash point:
150 °C
Atm. press.:
760 mm Hg

Replication

Flash Point (°C)

R1

150.0

R2

150.0

R3

150.0

Mean (°C)

150.0

Standard Deviation

0.00

Interpretation of results:
GHS criteria not met
Conclusions:
The mean flash point of FRET 12-0492 was 150.0 ± 0.00°C at normal atmospheric pressure (i.e. 760 mm Hg)
Executive summary:

The mean flash point of FRET 12-0492 was 150.0 ± 0.00°C at normal atmospheric pressure (i.e. 760 mm Hg)

Description of key information

The mean flash point of FRET 12-0492 was 150.0 ± 0.00°C at normal atmospheric pressure (i.e. 760 mm Hg)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
94 °C

Additional information