Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
30 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D 6450
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH FLP, Grabner Instruments, Austria

Test material

Constituent 1
Reference substance name:
Fir, Abies balsamea, ext.
EC Number:
285-364-0
EC Name:
Fir, Abies balsamea, ext.
Cas Number:
85085-34-3
IUPAC Name:
Fir Balsam Oil
Test material form:
liquid
Details on test material:
Name of test material as cited in study report: Fir Needle Oil Canadian (Fir, Abies Balsamea, ext)

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Botanical source and Lot# 67919
- Expiration date of the lot/batch: 13 septembre 2018
- Purity test date: UVCB, considered 100% pure

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature (15-25 °C, ≤ 70 RH%), protected from light, avoid contact with iron.

Results and discussion

Flash point
Flash point:
43.1 °C
Atm. press.:
98.1 kPa

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The measured flashpoint of Fir Needle Oil Canadian, using the closed-cup method, is 43.1 °C. It is classified as a flammable liquid category 3.