Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Type of method:
Laser scattering/diffraction
Key result
Percentile:
D50
Mean:
549 µm
St. dev.:
12
Conclusions:
The test item EDTA-CoNa2 has a median particle size D50 = 549 µm, which was determined by laser diffraction measurement.

Description of key information

Additional information

The test item EDTA-CoNa2 has a median particle size D50 = 549 µm, which was determined by laser diffraction measurement.