Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
27000 mPa.s at 25 degee C
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Supplier: Borica Co., Ltd.
- Lot number: 110422Y
- Expiration date of the lot/batch: 2017-Dec-12
- CAS number: 101033-44-7
Key result
Flash point:
ca. 90.1 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flammable liquid of the test substance was 90.1 degree C under 1 atm following ASTM D93 method using Pensky-Marten apparatus. The substance was classified as combustible liquid Category 4 according to GHS rules, but not sufficient for flammable liquid according to CLP Regulations.
Executive summary:

The substance was classified as combustible liquid Category 4 according to GHS rules, but not sufficient for flammable liquid according to CLP Regulations.

Description of key information

ASTM D93 closed cup method using Pensky-Martens apparatus.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
90.1 °C

Additional information