Registration Dossier

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose:
data waiving: supporting information
Reference
Endpoint:
self-heating substances / mixtures
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 March 2017 - 05 May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
UN Manual of Tests and Criteria: Test N.4 (Test method for self-heating substances)
Version / remarks:
Rev. 6 (2015)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Specific details on test material used for the study:
decomposition temp.: 175°C
Key result
Test procedure:
100 mm sample cube at 140°C
Result:
negative outcome (no effect observed)

An exothermic effect of the test item by self-heating was observed at an oven temperature of 142°C. During this effect the test item reached a temperature of 152°C. According to the guideline, the test is positive when the sample temperature exceeds the oven temperature by 60°C during the 24 hour testing time. Based on this, the result is considered negative and it demonstrated that the test item is “not a self-heating substance”.

After the experiment, the test item had turned into a darker pink residue. The change of colour might be due to decomposition/reaction.

 

Interpretation of results:
other: not classified based on GHS or CLP criteria
Conclusions:
The substance is not self-heating.

Executive summary:

In a GLP study according to UN Test N.4, a negative result was obtained using a 10 cm sample cube at 140°C. From this it was concluded that C.I. Pigment Red 81:2 is not a self-heating substance.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion