Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because water solubility is below 1 mg/L at 20°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 08 Mar 2018 to 25 Mar 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method
Key result
Water solubility:
< 0.001 mg/L
Temp.:
20 °C
pH:
7.2
Remarks on result:
not determinable
Details on results:
No test item was detected at either flow rate.



Conclusions:
The water solubility of the substance at 20°C was determined to be <0.0011 mg/L.
Executive summary:

The water solubility of the substance was determined using the column elution method in a GLP study according to EC A.6, OECD 105 and OPPTS 830.7840.

Five samples were analysed at two flowrates (24 and 12 ml/h). Analysis was performed by a validated GC-FID method. No test item was detected at either flow rate. The water solubility of the substance at 20°C was determined to be below the linit of detection, i.e. <0.0011 mg/L. The pH of the water samples was 7.2.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion