Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Burning time:
< 4 min

The test item was observed to ignite after 2 seconds of application of the burner flame. The flame propagated along 200 mm of the train in a total of 3 minutes and 58 seconds. As this was shorter than the limit of 4 minutes, the test item was considered to be highly flammable.

As no further test item was available, the test was concluded at this preliminary stage.

Interpretation of results:
Category 1 (flammable solids) based on GHS criteria
Conclusions:
The test item was found to be highly flammable in a preliminary test. As no further test item was available, the test was concluded at this preliminary stage.
Executive summary:

The flammability of the test item was investigated in an EC Method A.10 study. The test item was observed to ignite after 2 seconds of application of the burner flame. The flame propagated along 200 mm of the train in a total of 3 minutes and 58 seconds. As this was shorter than the limit of 4 minutes, the test item was considered to be highly flammable. As no further test item was available, the test was concluded at this preliminary stage.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The test item was observed to ignite after 2 seconds of application of the burner flame. The flame propagated along 200 mm of the train in a total of 3 minutes and 58 seconds. As this was shorter than the limit of 4 minutes, the test item was considered to be highly flammable. As no further test item was available, the test was concluded at this preliminary stage.

Key value for chemical safety assessment

Flammability:
flammable

Additional information

The flammability of the test item was investigated in an EC Method A.10 study (Dunning 2018).

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Justification for classification or non-classification

The test item was observed to ignite after 2 seconds of application of the burner flame. The flame propagated along 200 mm of the train in a total of 3 minutes and 58 seconds. As this was shorter than the limit of 4 minutes, the test item was considered to be highly flammable.

As no further test item was available, the test was concluded at this preliminary stage, and the substance was assigned a precautionary classification as a category 1 flammable solid; until a definitive test can be performed.