Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No testmethod has been identified

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Not refered to guideline: therefore Klimish code 2
The Particle size was determined by Laser Diffraction using a Shimazu SALD7000 instrument
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of distribution:
counted distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
ca. 7.579 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
other: unknown
Mean:
ca. 7.37 µm
St. dev.:
0.206

Applicant's summary and conclusion

Conclusions:
A Median diameter of 7.579 µm was measured.