Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
sieving
Qualifier:
according to guideline
Guideline:
other: ASTM C136
Qualifier:
according to guideline
Guideline:
other: AASHTO T 27
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
other: sieving
Mass median aerodynamic diameter:
ca. 20 µm
Remarks on result:
other: standard deviation not measured -- no statitisc values
Percentile:
D10
Mean:
ca. 20 µm
Remarks on result:
other: St deviation not known
Percentile:
D50
Mean:
ca. 60 µm
Remarks on result:
other: St deviation not known
Percentile:
D90
Mean:
460 µm
Remarks on result:
other: st deviation not known
No.:
#1
Size:
>= 1 000 µm
Distribution:
ca. 1.2 %
No.:
#2
Size:
>= 500 - < 1 000 µm
Distribution:
ca. 12.8 %
No.:
#3
Size:
>= 250 - < 500 µm
Distribution:
ca. 12.4 %
No.:
#4
Size:
>= 160 - < 250 µm
Distribution:
ca. 2.8 %
No.:
#5
Size:
>= 63 - < 160 µm
Distribution:
ca. 28 %
No.:
#6
Size:
>= 40 - < 63 µm
Distribution:
ca. 36 %
No.:
#7
Size:
> 40 µm
Distribution:
ca. 6.8 %
Conclusions:
According to a granulometry study (sieving) OECD 110, the mean diameter of DBTU is about 60 um, D10 equals 20 um and D90um is 460 um

Since the inhalable fraction is 42.8% (i.e. 428 000mg/kg >> 5000 mg/kg), DBTU is considered as having extremely fine particles.

Description of key information

According to a granulometry study (sieving) OECD 110, the mean diameter of DBTU  is about 60 um, D10 equals 20 um and  D90um is 460 um

Since the inhalable fraction is 42.8% (i.e.  428 000mg/kg >> 5000 mg/kg), DBTU is considered as having extremely fine particles.

Additional information