Administrative data

First-aid measures

Inhalation

-Remove to fresh air. If not breathing, give artificial respiration by qualified personnel. If breathing is difficult, give oxygen. Get medical attention.

Eye contact

- Remove contact lenses (if any). Do not allow to rub eyes or keep eyes closed. Immediately flush eyes with plenty of running water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

Skin contact

- Rinse effected area with plenty of water for at least 15 minutes while removing contaminated clothing.

- If symptoms persist, get medical attention.

- Wash contaminated clothing before re-use. Destroy contaminated shoes.

Ingestion

- Wash out mouth with water, Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Loosen tight such as collar, tie, belt or waistband. Get medical attention.

Fire-fighting measures

Suitable extinguishing media

- Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Contact professional fire-fighters immediately. Cool containers with flooding quantities of water prevent rupture until well after fire is out. For small fires, do NOT use dry chemicals, carbon dioxide, halon or foams. USE WATER ONLY. For large fires flood fire with water from a distance.

Extinguishing media which must not be used for safety reasons

- None

Special exposure hazards in a fire

- Not flammable,

- During a fire, irritating and toxic gases may be generated by thermal decomposition

- Hydrochloric acid in excess can react with many metals to produce flammable hydrogen gas. Neutralize with limestone, slaked lime, or soda ash to minimize formation of potentially explosive hydrogen gas.

Special protective equipment for fire-fighters

- As in any fire, full protective gear and self contained breathing apparatus should be worn.

Accidental release measures

Refer also to protective measures listed in sections on handling & storage.

Environmental precautions

- Notify safety personnel of large leaks or spills. Ventilate area of leak or spill. Contain large spills, collect or flush water to a holding area for neutralization. Do not flush directly to sewer or surface waters. Surfaces contaminated this material and small spills or leaks should be covered with excess of a inorganic absorbent like lime, soda ash to neutralize. Place the neutralized material into containers suitable for eventual disposal, reclamation, destruction.

Methods for cleaning up

- Contain large spills, collect or flush water to a holding area for neutralization. Do not flush directly to sewer or surface waters.

- Surfaces contaminated with this material or small spills or leaks should be covered with excess of a inorganic absorbent like lime, soda ash to neutralize.

- Wash up with water using inorganic absorbent like lime or soda ash, neutralize with lime or soda ash, and flush area with water. Do not flush directly to sewer or surface waters.

- Keep in properly labeled, suitable, closed containers for disposal.

- Treat recovered material as described in the section "Disposal considerations"

Handling and storage

Handling

- Keep in a tightly closed container, stored in a cool, dry, well ventilated area. Protect against physical damage. Containers of this material may be hazardous when empty since they retain product residues (liquid, solids after long duration or drying of liquid); observe all warnings and precautions listed for the product.

Storage

- Keep in a cool, dry, well ventilated area.

- Store in original container.

- Keep container closed.

- Keep away from incompatible products (foodstuffs, reducing agents).

- Protect from physical damage, heat and sunlight.

Specific use(s)

- Use process enclosures, use adequate ventilation, or other engineering controls to keep airborne concentrations. If user operations generate fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.

- For further information, please contact: Supplier

Packaging material

- 1000 liter IBC’s containing 1300 kg net.

Other information

- With Lithium + nitrogen will ignite.

- Prevent formation of aerosols

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3264
Shippingopen allclose all
Labels:
8
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
3264
Shippingopen allclose all
Labels:
8
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3264
Shipping information
Proper shipping name and description:
N.O.S. (HYDROCHLORIC ACID)
Chemical name:
N.O.S. (HYDROCHLORIC ACID)
Labels:
8
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3264
Shipping information
Proper shipping name and description:
N.O.S. (HYDROCHLORIC ACID)
Chemical name:
N.O.S. (HYDROCHLORIC ACID)
Labels:
8
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

· 8.2 Exposure controls

· Personal protective equipment

· General protective and hygienic measures

Keep away from foodstuffs, beverages and food.

Wash hands during breaks and at the end of the work.

· Breathing equipment:

In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or

longer exposure use breathing apparatus that is independent of circulating air.

· Protection of hands:

The glove material has to be impermeable and resistant to the product/ the substance/ the

preparation.

Selection of the glove material on consideration of the penetration times, rates of diffusion and the

degradation

· Material of gloves

The selection of the suitable gloves does not only depend on the material, but also on further marks

of quality and varies from manufacturer to manufacturer. As the product is a preparation of several

substances, the resistance of the glove material can not be calculated in advance and has therefore

to be checked prior to the application.

· Penetration time of glove material

The exact break trough time has to be found out by the manufacturer of the protective gloves and

has to be observed.

· Eye protection: Safety glasses recommended during refilling.

Body protection: suitable clothing

Stability and reactivity

10.1 Reactivity No dangerous reaction known under conditions of normal use.

10.2 Chemical stability

· Thermal decomposition / conditions to be avoided:

No decomposition if used according to specifications.

· 10.3 Possibility of hazardous reactions No dangerous reactions known

· 10.4 Conditions to avoid No further relevant information available.

· 10.5 Incompatible materials: No further relevant information available.

· 10.6 Hazardous decomposition products:

Hydrogen chloride (HCl)

Chlorine

Disposal considerations

13.1 Waste treatment methods

· Recommendation Must be specially treated under adherence to official regulations.