Registration Dossier

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 May 2016 - 09 Sep 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reference:
Composition 0
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
Attached to the study report
Type of method:
pycnometer method
Test material information:
Composition 1
Specific details on test material used for the study:
- Batch n°: I15AB0305
- Analytical purity: 99.7%
- Expiry/retest date: 23/01/2017
- Test item storage conditions: At room temperature
Key result
Type:
density
Density:
1.19 g/cm³
Temp.:
20 °C
Remarks on result:
other: The difference between the results of the two measurements was < 0.02 g/cm³. According to the guideline, the density of the test item is therefore given as the mean value.

The density (ρ) of a substance is the quotient of its mass and its volume and is expressed in SI units of kg/m³.

The individual measurements were obtained with an accuracy of <0.02 g/cm³.

The individual density measurements were 1.196 g/cm³ (test 1) and 1.189 g/cm³ (test 2).

Conclusions:
The density of the test item at 20ºC was 1.19 g/cm³ (1.19 x 10³ kg/m³).

Description of key information

The density of T003422 was determined to be 1.19 g/cm3at 20°C in a GLP study in accordance with

OECD Guideline 109, EU Method A.3 and EPA OPPTS 830.7300 (K1, Ciric, 2017).

Key value for chemical safety assessment

Additional information