Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Supplier: Borica Co., Ltd.
- Lot number: 000454P
- Expiration date of the lot/batch: 2018-May-04
- CAS number: 61417-49-0

Key result
Temp.:
other: 25°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 150
Conclusions:
The viscosity of the target substance is 150 mPa.s at 25°C, using rotational viscometer.

Description of key information

Key value for chemical safety assessment

Viscosity:
150 mPa · s (dynamic)
at the temperature of:
25 °C

Additional information