Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 208-854-8 | CAS number: 543-94-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 5 July 2017 to 13 July 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 13320 (Particle size analysis - Laser diffraction methods)
- GLP compliance:
- not specified
- Other quality assurance:
- ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
- Type of method:
- Laser scattering/diffraction
- Type of particle tested:
- primary particle
- Type of distribution:
- volumetric distribution
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 17025 25/26/28
- Expiration date of the lot/batch:13 May 2020
- Manufacturing date: 13 may 2017
Strontium diacetate used as test item is hemihydrated - Mass median aerodynamic diameter:
- 72 µm
- Percentile:
- D10
- Mean:
- 15.81 µm
- St. dev.:
- 47.22
- Percentile:
- D50
- Mean:
- 72.16 µm
- St. dev.:
- 47.22
- Percentile:
- D90
- Mean:
- 142.8 mm
- St. dev.:
- 47.22
- No.:
- #1
- Size:
- 0 µm
- Distribution:
- 0 %
- No.:
- #2
- Size:
- 10 µm
- Distribution:
- 6.63 %
- No.:
- #3
- Size:
- 20 µm
- Distribution:
- 12.4 %
- No.:
- #4
- Size:
- 25 µm
- Distribution:
- 15.4 %
- No.:
- #5
- Size:
- 32 µm
- Distribution:
- 19.8 %
- No.:
- #6
- Size:
- 50 µm
- Distribution:
- 32.9 %
- No.:
- #7
- Size:
- 63 µm
- Distribution:
- 43 %
- No.:
- #8
- Size:
- 71 µm
- Distribution:
- 49.1 %
- No.:
- #9
- Size:
- 75 µm
- Distribution:
- 52.1 %
- No.:
- #10
- Size:
- 90 µm
- Distribution:
- 63 %
- No.:
- #10
- Size:
- 100 µm
- Distribution:
- 69.6 %
- Conclusions:
- The median particle size D50 of the test item deduced from the particle size distributions was : 72.16 micrometer.
The particle size D10 of the test item deduced from the particle sizedistributions was :15.81 micrometer.
The particle size D90 of the test item deduced from the particle size distributions was : 142.8 micrometer. - Executive summary:
The particle size distribution of strontium diacetate was determined following ISO 13320 (Particle size analysis - Laser diffraction methods).
The particle size distributions were determined in a test serie. For the test serie fraction (left axis of the ordinate) and the shiftings (right axis of the ordinate) are presented in percent by volume as a function
of the particle size. Median value was calculated from unrounded values.
The median particle size D50 of the test item deduced from the particle size distributions was : 72.16 micrometer.
The particle size D10 of the test item deduced from the particle size distributions was : 15.81 micrometer.
The particle size D90 of the test item deduced from the particle size distributions was : 142.8 micrometer.
Reference
Description of key information
The particle size distribution of strontium diacetate was determined following ISO 13320 (Particle size analysis - Laser diffraction methods).
The particle size distributions were determined in a test serie. For the test serie fraction (left axis of the ordinate) and the shiftings (right axis of the ordinate) are presented in percent by volume as a function of the particle size. Median value was calculated from unrounded values.
The median particle size D50 of the test item deduced from the particle size distributions was : 72.16 micrometer.
The particle size D10 of the test item deduced from the particle size distributions was : 15.81 micrometer.
The particle size D90 of the test item deduced from the particle size distributions was : 142.8 micrometer.
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.