Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reference:
Composition 0
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to
Guideline:
other: NIEA R210.23 C
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
300 mPa.s at 25°C
Test material information:
Composition 1
Key result
Flash point:
ca. 104 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the target substance was 104°C and therefore did not meet GHS standards of flammable liquid.

Description of key information

According tot ASTM D93 method using Pensky Martens closed cup apparatus.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information