Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: NIEA R210.23 C
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
300 mPa.s at 25°C
Key result
Flash point:
ca. 104 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the target substance was 104°C and therefore did not meet GHS standards of flammable liquid.

Description of key information

According tot ASTM D93 method using Pensky Martens closed cup apparatus.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information