Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 July 2017 - 16 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
not specified
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
not specified
GLP compliance:
yes (incl. certificate)
Type of method:
capillary method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
Batch: 1B182601
Purity: 99.86%

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
< -20 °C
Decomposition:
no
Sublimation:
no

Applicant's summary and conclusion

Conclusions:
Observations: The test item did not change in appearance during cooling.
Result: Freezing point: <-20 °C (<253 K).