Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 21 November 2017 Experimental completion date: 28 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Benzyl acrylate
EC Number:
219-673-9
EC Name:
Benzyl acrylate
Cas Number:
2495-35-4
Molecular formula:
C10H10O2
IUPAC Name:
benzyl acrylate
Specific details on test material used for the study:
Identification: BZA
Chemical name: Benzyl acrylate
CAS number: 2495-35-4
Appearance/physical state: clear colorless liquid
Batch: 1B182601
Purity: 99.86%
Expiry date: 06 March 2018
Storage conditions: room temperature, in the dark

Results and discussion

Flash point
Flash point:
>= 104 - <= 108 °C
Atm. press.:
100.8 kPa

Any other information on results incl. tables

Results of the flash point determination are shown in the following table:

Test Temperature (ºC) Observations
21.0 No flash.
26.0 No flash.
31.0 No flash.
36.0 No flash.
41.0 No flash.
46.0 No flash.
51.0 No flash.
56.0 No flash.
61.0 No flash.
66.0 No flash.
71.0 No flash.
71.0 (fresh sample) No flash.
76.0 No flash.
81.0 No flash.
86.0 No flash.
91.0 No flash.
96.0 No flash.
101.0 (fresh sample) No flash.
106.0 A blue flash spread across the sample cup
106.0 (fresh sample) A blue flash spread across the sample cup.
101.0 (fresh sample) No flash.
102.0 (fresh sample) No flash.
103.0 (fresh sample) No flash.
104.0 (fresh sample) No flash.
105.0 (fresh sample) A blue flash spread across the sample cup.
105.0 (fresh sample) No flash.
106.0 (fresh sample) A blue flash spread across the sample cup.
104.0 (fresh sample) No flash.

Atmospheric pressure: 100.8 kPa Observed flash point: 106.0 °C Corrected flash point: 106.1 °C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 106 ± 2 °C.
Executive summary: